Mercedes-Benz Mercedes Sprinter 2006-2018 HVAC Specifications
Explore detailed HVAC specifications for the 2006-2018 Mercedes Sprinter, including air conditioning, heating, ventilation, and climate control systems. Ideal for maintenance, repair, and upgrades.
Overview Specifications
This document provides detailed specifications and information about the HVAC (Heating, Ventilation, and Air Conditioning) system for Mercedes Sprinter vehicles manufactured between 2006 and 2018. It is designed to assist users in understanding the system's components, functionality, and maintenance. The guide includes sections on system components, operational features, and troubleshooting tips. Use the search functionality to quickly locate specific terms or navigate through sections to explore detailed information about the HVAC system.
How to Use
Use the search bar to enter keywords related to the HVAC system, such as 'blower motor' or 'refrigerant type'. This will highlight relevant sections and technical points for quick access.
Navigate through the document by scrolling or clicking on section titles in the table of contents. Each section is organized into subsections with detailed points for easy reference.
Key Specifications
Refrigerant Type
R134a
Temperature Range
16°C to 32°C
Blower Motor Speeds
3 to 5 speeds
Airflow Capacity
400-600 m³/h
Defrosting Time
3-5 minutes
Available Specifications
HVAC System Components
This section covers the primary components of the Mercedes Sprinter HVAC system, including the blower motor, evaporator, condenser, and compressor. Understanding these parts is essential for maintenance and troubleshooting.
HVAC System Components
This section covers the primary components of the Mercedes Sprinter HVAC system, including the blower motor, evaporator, condenser, and compressor. Understanding these parts is essential for maintenance and troubleshooting.
Blower Motor
- Located in the HVAC housing unit
- Responsible for circulating air through the vents
- Controlled by the HVAC control panel
- Available in single or multi-speed configurations
Evaporator and Condenser
- Evaporator cools the air inside the cabin
- Condenser releases heat absorbed from the cabin
- Both components are part of the refrigerant cycle
- Require periodic cleaning to maintain efficiency
Operational Features
This section explains the operational features of the HVAC system, including temperature control, air distribution, and defrosting capabilities. It also covers the system's integration with the vehicle's electronics.
Operational Features
This section explains the operational features of the HVAC system, including temperature control, air distribution, and defrosting capabilities. It also covers the system's integration with the vehicle's electronics.
Temperature Control
- Manual or automatic climate control options
- Temperature range from 16°C to 32°C (60°F to 90°F)
- Sensors monitor cabin temperature
- Feedback system for precise adjustments
Air Distribution
- Adjustable vents for directional airflow
- Options for floor, dashboard, and windshield vents
- Recirculation mode for improved efficiency
- Automatic mode for balanced air distribution
Maintenance and Troubleshooting
This section provides tips for maintaining the HVAC system and troubleshooting common issues. Regular maintenance ensures optimal performance and longevity of the system.
Maintenance and Troubleshooting
This section provides tips for maintaining the HVAC system and troubleshooting common issues. Regular maintenance ensures optimal performance and longevity of the system.
Refrigerant Management
- Use R134a refrigerant type
- Check refrigerant levels annually
- Refill if cooling performance decreases
- Inspect for leaks during routine maintenance
Common Issues
- Weak airflow due to clogged filters
- Unusual noises from the blower motor
- Inconsistent temperature control
- Defrosting inefficiency during winter
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
Overview
- Type
- Dual-Zone Automatic Climate Control
- Configuration
- Front and Rear System
- Platform
- Sprinter Van
- Material
- High-Density Plastic and Aluminum
- Location
- Dashboard and Rear Cabin
Dimensions
- Front Unit Width
- 18.5 in (470 mm)
- Front Unit Height
- 6.3 in (160 mm)
- Front Unit Depth
- 8.7 in (220 mm)
- Rear Unit Width
- 14.2 in (360 mm)
- Rear Unit Height
- 5.9 in (150 mm)
- Rear Unit Depth
- 7.1 in (180 mm)
- Duct Diameter
- 3.1 in (80 mm)
Materials
- Housing
- High-Density Plastic
- Heat Exchanger
- Aluminum
- Blower Motor
- Copper Windings
- Filters
- Polyester and Activated Carbon
Features
- Temperature Control
-
- Dual-Zone Automatic
- Digital Display
- Temperature Memory
- Quick Cool Function
- Air Flow
-
- Multi-Level Fan Speeds
- Directional Vents
- Rear Air Distribution
- Defrost Mode
- Filtration
-
- Cabin Air Filter
- Activated Carbon Filter
- Pollen Filter
- Odor Reduction
- integration
-
- Steering Wheel Controls
- Central Display Integration
- Voice Command Compatibility
- Remote Start Pre-Conditioning
- Safety
-
- Overheat Protection
- Automatic Shutdown
- Filter Replacement Indicator
Safety Features
- Overheat Protection
-
- Automatic Shutdown at High Temperatures
- Thermal Fuse
- System Monitoring
-
- Filter Clog Detection
- Compressor Overload Protection
- Air Quality
-
- CO2 Sensor
- Automatic Recirculation Mode
Comfort Features
- Temperature Management
-
- Precise Dual-Zone Control
- Auto Mode for Optimal Comfort
- Air Distribution
-
- Adjustable Vents
- Footwell Airflow
- Rear Cabin Ventilation
- Noise Reduction
-
- Quiet Blower Motor
- Sound-Dampening Ducts
- Convenience
-
- Remote Start Climate Control
- Steering Wheel Controls
Accessories
- Filters
-
- Standard Cabin Filter
- Activated Carbon Filter
- Pollen Filter
- Upgrades
-
- Rear HVAC Unit
- Additional Vents
- Heated Seats Integration
- Tools
-
- Diagnostic Scanner
- Filter Replacement Kit
- Duct Cleaning Brush
Maintenance
- Service interval
- Every 15,000 miles or 12 months
- Service Items
-
- Cabin Air Filter Replacement
- System Diagnostics
- Duct Cleaning
- Refrigerant Level Check
- Blower Motor Inspection
- Maintenance Notes
-
- Use only OEM filters for optimal performance
- Check refrigerant levels annually
- Inspect ducts for blockages
Warranty
- Basic
- Miles: 50,000Years: 4Coverage: Parts and Labor
- Powertrain
- Miles: 100,000Years: 7Coverage: Compressor and Blower Motor
- Corrosion
- Miles: UnlimitedYears: 10Coverage: HVAC Housing
- Emissions
- Miles: 80,000Years: 5Coverage: Refrigerant System
- Warranty Terms
-
- Valid only with authorized service
- Excludes wear items like filters
Production Details
- Manufacturer
- Mercedes-Benz
- Manufacturing Process
-
- Precision Molding for Housing
- Robotic Assembly
- Quality Control Testing
- Quality Control
- Leak Testing: Compulsory for Refrigerant LinesPerformance Testing: System Efficiency VerificationDurability Testing: Blower Motor Longevity Test
- Sustainability Practices
-
- Recyclable Materials
- Low-Emission Refrigerant
- Energy-Efficient Production
- Production Metrics
-
- Annual Output: 500,000 Units
- Defect Rate: <0.1%
- Energy Consumption: 15 kWh/Unit
Service Information for HVAC Service
Maintenance and service requirements specific to the HVAC system
- Replace Cabin Air Filter
- Check Refrigerant Levels
- Inspect Ducts for Blockages
- Test Blower Motor Function
- Run System Diagnostics
Ensure use of OEM filters for optimal performance
- Replace Activated Carbon Filter
- Clean Evaporator Coil
- Inspect Compressor Operation
- Check for Refrigerant Leaks
- Test Airflow Distribution
Requires specialized tools for refrigerant checks
- Replace Blower Motor if Necessary
- Overhaul HVAC System
- Replace Refrigerant
- Test System Efficiency
- Inspect All Electrical Connections
Major service requires certified technician
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 Is the HVAC system compatible with all 2006-2018 Mercedes Sprinter models?
Is the HVAC system compatible with all 2006-2018 Mercedes Sprinter models?
The HVAC system is designed to be compatible with all 2006-2018 Mercedes Sprinter models, including both diesel and gasoline variants. However, specific configurations such as extended wheelbase or high-roof models may require additional components. Always verify compatibility using the vehicle's VIN and consult the manufacturer's guidelines for precise specifications.
Q2 What are the maintenance requirements for the HVAC system in a 2006-2018 Mercedes Sprinter?
What are the maintenance requirements for the HVAC system in a 2006-2018 Mercedes Sprinter?
Regular maintenance includes inspecting and replacing the cabin air filter every 15,000-20,000 miles, checking refrigerant levels annually, and ensuring the compressor and blower motor are functioning properly. It's also recommended to inspect hoses and seals for leaks every 30,000 miles. Adhering to the manufacturer's maintenance schedule ensures optimal performance and longevity.
Q3 How do I replace the HVAC blower motor in a 2006-2018 Mercedes Sprinter?
How do I replace the HVAC blower motor in a 2006-2018 Mercedes Sprinter?
To replace the HVAC blower motor, first disconnect the battery. Remove the glove box assembly to access the blower motor. Disconnect the electrical connector and mounting screws, then carefully remove the motor. Install the new motor, reconnect the electrical connector, and reattach the glove box. Reconnect the battery and test the system to ensure proper operation.
Q4 What should I do if the HVAC system in my 2006-2018 Mercedes Sprinter is not cooling?
What should I do if the HVAC system in my 2006-2018 Mercedes Sprinter is not cooling?
If the HVAC system is not cooling, check the refrigerant levels and inspect for leaks. Ensure the compressor is engaging when the AC is turned on. Verify that the cabin air filter is clean and not obstructing airflow. If issues persist, inspect the blower motor, condenser, and evaporator for faults. Seek professional assistance if necessary.
Q5 How can I optimize the performance of the HVAC system in my 2006-2018 Mercedes Sprinter?
How can I optimize the performance of the HVAC system in my 2006-2018 Mercedes Sprinter?
To optimize performance, regularly clean or replace the cabin air filter, ensure refrigerant levels are correct, and inspect the system for leaks. Use the recirculation mode in extreme temperatures to reduce strain on the system. Periodically clean the condenser and evaporator coils. Following these practices ensures efficient operation and extends the system's lifespan.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
Mercedes Sprinter HVAC Service Manual
Coming SoonComprehensive guide covering HVAC system maintenance, troubleshooting, and repair procedures for 2006-2018 Mercedes Sprinter models.
HVAC System Technical Bulletin
Coming SoonLatest updates and technical service bulletins for the HVAC system in 2006-2018 Mercedes Sprinter vehicles.
Mercedes Sprinter HVAC Parts Catalog
Coming SoonDetailed catalog of HVAC components and accessories for 2006-2018 Mercedes Sprinter models.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.